|

Build Your Online Product Catalogs?
Product Name: |
8-0108-0003-ISO Emerson Turbidity Meter Sensor
|
Supply Ability: |
1000 |
Related proudcts |
|
Specifications |
3-5KG |
Price Term: |
EXW |
Port of loading: |
SHANGHAI |
Minimum Order |
1 |
Unit Price: |
12000 |
|
8-0108-0003-ISO Emerson Turbidity Meter Sensor 2. Sensor technical specifications (8-0108-0003-ISO replaceable sensors in accordance with international ISO standards) Environmental standards: US EPA180.1 or international ISO 7027 [using 860nm LED light source) must be explained when ordering Incandescent lamp life: about 2 years LED life: about 5 years Dimensions: about 5.2 inches X 3.0 inches (diameter) [132 mm * 76 mm) Material in contact with the process liquid: Delrin, glass, EPD Accuracy after calibration with 20NTU calibration cup: 0-1 NTU, ¡À2% of reading or ¡À0,015 NTU, taking a larger value; 0-20 NTU, ¡À2% of reading Cable length: 20 feet (6.1 meters) or 50 feet (15.2 meters), up to 50 feet [15.2 meters) cable connector protection class IP65 Final pressure: 30psig (308KPA, absolute pressure) Temperature: 3-35 ¡ã C Protection level : IP65 Bubble flow cell specifications Dimensions: 18.1 inches (460 mm) long, 4.1 inches (104 mm) Material in contact with process liquid: ABS, EPDM, Delrin, polypropylene, nylon Inlet size: 1/4" (OD) ferrule connector, you can also remove the connector to become 1/4" FNPT Discharge port size: The spine connector is connected to the 3/8¡± (ID) line, and the connector can also be removed to become a 1/4¡± FNPT. The discharge port must be straight out of the atmosphere Sampling temperature: 40-95 ¡ãF (5-35 ¡ã C) Minimum sampling pressure: 3.5 psig (125KPA, absolute pressure), at which point the sample flow rate is approximately 250 ml / hour Maximum sampling pressure: 30psig (308KPA, absolute pressure) discharge pipe can not be blocked Recommended sampling flow: 250-750 ml / min Weight / Shipping Weight: Sensor: 1 lb / 2 lb [0.5 kg / 1.0 kg) Analyzer: 2 lbs / 3 lbs [1.0 kg / 1.5 kg)
Turbidity 1-0901-0009-EPA: Backup Lamp, EPA 1-0901-0010-ISO: ***re lamp, ISO 8-0108-0003-ISO: Turbidity sensor, ISO 8-0108-0002-EPA: Turbidity sensor, EPA 060-761855: Premixed 4000 NTU Formazin Calibration Kit 24097-00: sensor cable, turbidity, 20' 24101-00: Calibrat |
Company: |
Decomont Process Control (Wuhan) Co., Ltd.
|
Contact: |
Ms. Zhang Jia ping |
Address: |
901, Building D1, Zhongnan International City, Zhongnan Road, Wuchang District |
Postcode: |
|
Tel: |
15527360871 |
Fax: |
027-51013521 |
E-mail: |
|
|
|
|